1. BIẾN TẦN A1000 YASKAWA
200-240V, 3-Phase, Protected Chassis/NEMA 1
Normal Duty (ND)1
|
Heavy Duty (HD)1
|
Standard Enclosure
|
|||
Rated Output Current (Amps)
|
Nominal HP2
|
Rated Output Current (Amps)
|
Nominal HP2
|
||
CIMR-AU2A0004FAA
|
3.5
|
3/4
|
3.2
|
3/4
|
NEMA 1
|
CIMR-AU2A0006FAA
|
6
|
1
|
5
|
1
|
|
CIMR-AU2A0008FAA
|
8
|
2
|
6.9
|
2
|
|
CIMR-AU2A0010FAA
|
9.6
|
2
|
8
|
2
|
NEMA 1
|
CIMR-AU2A0012FAA
|
12
|
3
|
11
|
3
|
|
CIMR-AU2A0018FAA
|
17.5
|
5
|
14
|
3
|
|
CIMR-AU2A0021FAA
|
21
|
7.5
|
17.5
|
5
|
NEMA 1
|
CIMR-AU2A0030FAA
|
30
|
10
|
25
|
7.5
|
|
CIMR-AU2A0040FAA
|
40
|
15
|
33
|
10
|
|
CIMR-AU2A0056FAA
|
56
|
20
|
47
|
15
|
NEMA 1
|
CIMR-AU2A0069FAA
|
69
|
25
|
60
|
20
|
|
CIMR-AU2A0081FAA
|
81
|
30
|
75
|
25
|
|
CIMR-AU2A0110FAA
|
110
|
40
|
85
|
30
|
NEMA 1
|
CIMR-AU2A0138FAA
|
138
|
50
|
115
|
40
|
|
CIMR-AU2A0169FAA
|
169
|
60
|
145
|
50
|
NEMA 1
|
CIMR-AU2A0211FAA
|
211
|
75
|
180
|
60
|
|
CIMR-AU2A0250AAA
|
250
|
100
|
215
|
75
|
Protected Chassis
|
CIMR-AU2A0312AAA
|
312
|
125
|
283
|
100
|
|
CIMR-AU2A0360AAA
|
360
|
150
|
346
|
125
|
Protected Chassis
|
CIMR-AU2A0415AAA | 415 | 175 | 415 | 150 |
- Normal Duty overload current rating is 120% of rated output current for 60 seconds; Heavy Duty overload current rating is 150% of rated output current for 60 seconds
- Horsepower rating is based on standard NEMA B 4-pole motor design as represented in NEC table 430.150 Full-Load Current, Three-Phase Alternating Current Motors. Also, listed power ratings assumes three-phase input. For single-phase input applications, consult Manual Supplement TOEPYEASUP03 for proper sizing.
200-240V, 3-Phase, Flange
Normal Duty (ND)2
|
Heavy Duty (HD)2
|
Enclosure1
|
|||
Rated Output Current (Amps)
|
Nominal HP3
|
Rated Output Current (Amps)
|
Nominal HP3
|
||
CIMR-AU2A0004UAA
|
3.5
|
3/4
|
3.2
|
3/4
|
Flange
|
CIMR-AU2A0006UAA
|
6
|
1
|
5
|
1
|
|
CIMR-AU2A0008UAA
|
8
|
2
|
6.9
|
2
|
|
CIMR-AU2A0010UAA
|
9.6
|
3
|
8
|
2
|
Flange
|
CIMR-AU2A0012UAA
|
12
|
3
|
11
|
3
|
|
CIMR-AU2A0018UAA
|
17.5
|
5
|
14
|
3
|
|
CIMR-AU2A0021UAA
|
21
|
7.5
|
17.5
|
5
|
Flange
|
CIMR-AU2A0030UAA
|
30
|
10
|
25
|
7.5
|
|
CIMR-AU2A0040UAA
|
40
|
15
|
33
|
10
|
|
CIMR-AU2A0056UAA
|
56
|
20
|
47
|
15
|
Flange
|
CIMR-AU2A0069UAA
|
69
|
25
|
60
|
20
|
|
CIMR-AU2A0081UAA
|
81
|
30
|
75
|
25
|
|
CIMR-AU2A0110UAA
|
110
|
40
|
85
|
30
|
Flange
|
CIMR-AU2A0138UAA
|
138
|
50
|
115
|
40
|
|
CIMR-AU2A0169UAA
|
169
|
60
|
145
|
50
|
|
CIMR-AU2A0211UAA
|
211
|
75
|
180
|
60
|
Flange
|
CIMR-AU2A0250UAA
|
250
|
100
|
215
|
75
|
|
CIMR-AU2A0312UAA
|
312
|
125
|
283
|
100
|
|
CIMR-AU2A0360UAA
|
360
|
150
|
346
|
125
|
Flange
|
CIMR-AU2A0415UAA
|
415
|
175
|
415
|
150
|
- Standard Enclosure can be conventionally mounted, or heatsink external (kit required for models CIMR-AU2A081FAA and smaller). Flange Enclosure includes special factory-installed gasketing and flange to provide NEMA 12 backside integrity when mounting heatsink external.
- Normal Duty overload current rating is 120% of rated output current for 60 seconds; Heavy Duty overload current rating is 150% of rated output current for 60 seconds
- Horsepower rating is based on standard NEMA B 4-pole motor design as represented in NEC table 430. 150 Full-Load Current, Three-Phase Alternating Current Motors
240V, Single-Phase Input, (208-230V Three-Phase Output)
Single Phase Input – Sizing Method A (A)
(continuous full power) |
Single Phase Input – Sizing Method B (B)
(86% max power of connected motor size) |
|||||
Without Additional Reactor
|
With Additional Reactor
|
|||||
Motor Amps | Motor Size (HP) | Motor Amps | Motor Size (HP) |
Motor Amps
|
Motor Size (HP)
|
|
CIMR-AU2A0004FAA
|
1.7
|
1/3
|
2.4
|
1/2
|
2.4
|
1/2
|
CIMR-AU2A0006FAA
|
3.5
|
3/4
|
3.5
|
3/4
|
4.6
|
1
|
CIMR-AU2A0008FAA
|
4.6
|
1
|
4.6
|
1
|
4.6
|
1
|
CIMR-AU2A0010FAA
|
4.6
|
1
|
4.6
|
1
|
6.6
|
1.5
|
CIMR-AU2A0012FAA
|
6.6
|
1.5
|
7.5
|
2
|
7.5
|
2
|
CIMR-AU2A0018FAA
|
7.5
|
2
|
10.6
|
3
|
10.6
|
3
|
CIMR-AU2A0021FAA
|
7.5
|
2
|
10.6
|
3
|
10.6
|
3
|
CIMR-AU2A0030FAA
|
10.6
|
3
|
10.6
|
3
|
17.0
|
5
|
CIMR-AU2A0040FAA
|
10.6
|
3
|
17
|
5
|
17.0
|
5
|
CIMR-AU2A0056FAA
|
17
|
5
|
24
|
7.5
|
24.0
|
7.5
|
CIMR-AU2A0069FAA
|
24
|
7.5
|
31
|
10
|
31.0
|
10
|
CIMR-AU2A0081FAA
|
31
|
10
|
31
|
10
|
46
|
15
|
CIMR-AU2A0110FAA
|
31
|
10
|
46
|
15
|
46
|
15
|
CIMR-AU2A0138FAA
|
46
|
15
|
46
|
15
|
59
|
20
|
CIMR-AU2A0169FAA
|
59
|
20
|
59
|
20
|
75
|
25
|
CIMR-AU2A0211FAA
|
75
|
25
|
75
|
25
|
88
|
30
|
CIMR-AU2A0250AAA
|
88
|
30
|
88
|
30
|
114
|
40
|
CIMR-AU2A0312AAA
|
114
|
40
|
114
|
40
|
143
|
50
|
CIMR-AU2A0360AAA
|
143
|
50
|
143
|
50
|
169
|
60
|
CIMR-AU2A0415AAA |
169
|
60
|
169
|
60
|
211
|
75
|
- Standard Enclosure can be conventionally mounted, or heatsink external (kit required for models CIMR-AU2A0081FAA and smaller). Flange Enclosure includes special factory-installed gasketing and flange to provide NEMA 12 backside integrity when mounting heatsink external.
- Only models ending in FAA (CIMR-AU2A0211FAA and smaller) come standard with NEMA 1 End Cap Kits. Separately sold kits are available for larger models.
- For Flange Drives, use the sizing method above to determine proper drive size. Use selected model numbers with “UAA” suffix instead of “FAA” or “AAA” suffix.
- Use single phase input sizing method A for applications requiring more than 86% motor power. When sizing with additional reactor, refer to “Reactors for Single Phase Input” section of this price book. Caution: Adding more impedance than specified will degrade performance.
- Use single phase input sizing method B for applications requiring a maximum of 86% motor power.
380-480V, 3-Phase, Protected Chassis/NEMA 1
Normal Duty (ND)1
|
Heavy Duty (HD)1
|
Standard Enclosure
|
|||
Rated Output Current (Amps)
|
Nominal HP2
|
Rated Output Current (Amps)
|
Nominal HP2
|
||
CIMR-AU4A0002FAA
|
2.1
|
3/4 & 1
|
1.8
|
3/4
|
NEMA 1
|
CIMR-AU4A0004FAA
|
4.1
|
2
|
3.4
|
1 & 2
|
|
CIMR-AU4A0005FAA
|
5.4
|
3
|
4.8
|
3
|
|
CIMR-AU4A0007FAA
|
6.9
|
4
|
5.5
|
3
|
NEMA 1
|
CIMR-AU4A0009FAA
|
8.8
|
5
|
7.2
|
4
|
|
CIMR-AU4A0011FAA
|
11.1
|
7.5
|
9.2
|
5
|
|
CIMR-AU4A0018FAA
|
17.5
|
10
|
14.8
|
7.5 & 10
|
NEMA 1
|
CIMR-AU4A0023FAA
|
23
|
15
|
18
|
10
|
|
CIMR-AU4A0031FAA
|
31
|
20
|
24
|
15
|
|
CIMR-AU4A0038FAA
|
38
|
25
|
31
|
20
|
NEMA 1
|
CIMR-AU4A0044FAA
|
44
|
30
|
39
|
25 & 30
|
|
CIMR-AU4A0058FAA
|
58
|
40
|
45
|
30
|
|
CIMR-AU4A0072FAA
|
72
|
50
|
60
|
40
|
NEMA 1
|
CIMR-AU4A0088FAA
|
88
|
60
|
75
|
50 & 60
|
|
CIMR-AU4A0103FAA
|
103
|
75
|
91
|
60
|
|
CIMR-AU4A0139FAA
|
139
|
100
|
112
|
75
|
NEMA 1
|
CIMR-AU4A0165FAA
|
165
|
125
|
150
|
100
|
|
CIMR-AU4A0208AAA
|
208
|
150
|
180
|
125 & 150
|
Protected Chassis
|
CIMR-AU4A0250AAA
|
250
|
200
|
216
|
150
|
|
CIMR-AU4A0296AAA
|
296
|
250
|
260
|
200
|
|
CIMR-AU4A0362AAA
|
362
|
300
|
304
|
250
|
Protected Chassis
|
CIMR-AU4A0414AAA
|
414
|
350
|
370
|
300
|
|
CIMR-AU4A0515AAA
|
515
|
400
|
450
|
350
|
Protected Chassis
|
CIMR-AU4A0675AAA
|
675
|
500
|
605
|
400-500
|
|
CIMR-AU4A0930AAA
|
930
|
700-800
|
810
|
600-700
|
Protected Chassis
|
CIMR-AU4A1200AAA
|
1200
|
900-1000
|
1090
|
800-900
|
- Normal Duty overload current rating is 120% of rated output current for 60 seconds; Heavy Duty overload current rating is 150% of rated output current for 60 seconds
- Horsepower rating is based on standard NEMA B 4-pole motor design as represented in NEC table 430.150 Full-Load Current, Three-Phase Alternating Current Motors. Also, listed power ratings assumes three-phase input. For single-phase input applications, consult Manual Supplement TOEPYEASUP03 for proper sizing.
380-480V, 3-Phase, Flange
Normal Duty (ND)2
|
Heavy Duty (HD)2
|
Enclosure1
|
|||
Rated Output Current (Amps)
|
Nominal HP3
|
Rated Output Current (Amps)
|
Nominal HP3
|
||
CIMR-AU4A0002UAA
|
2.1
|
1
|
1.8
|
3/4
|
Flange
|
CIMR-AU4A0004UAA
|
4.1
|
2
|
3.4
|
1 & 2
|
|
CIMR-AU4A0005UAA
|
5.4
|
3
|
4.8
|
3
|
|
CIMR-AU4A0007UAA
|
6.9
|
4
|
5.5
|
3
|
Flange
|
CIMR-AU4A0009UAA
|
8.8
|
5
|
7.2
|
5
|
|
CIMR-AU4A0011UAA
|
11.1
|
7.5
|
9.2
|
5
|
|
CIMR-AU4A0018UAA
|
17.5
|
10
|
14.8
|
7.5 & 10
|
Flange
|
CIMR-AU4A0023UAA
|
23
|
15
|
18
|
10
|
|
CIMR-AU4A0031UAA
|
31
|
20
|
24
|
15
|
|
CIMR-AU4A0038UAA
|
38
|
25
|
31
|
20
|
Flange
|
CIMR-AU4A0044UAA
|
44
|
30
|
39
|
25 & 30
|
|
CIMR-AU4A0058UAA
|
58
|
40
|
45
|
30
|
|
CIMR-AU4A0072UAA
|
72
|
50
|
60
|
40
|
Flange
|
CIMR-AU4A0088UAA
|
88
|
60
|
75
|
50 & 60
|
|
CIMR-AU4A0103UAA
|
103
|
75
|
91
|
60
|
|
CIMR-AU4A0139UAA
|
139
|
100
|
112
|
75
|
Flange
|
CIMR-AU4A0165UAA
|
165
|
125
|
150
|
100
|
|
CIMR-AU4A0208UAA
|
208
|
150
|
180
|
125 & 150
|
Flange
|
CIMR-AU4A0250UAA
|
250
|
200
|
216
|
150
|
|
CIMR-AU4A0296UAA
|
296
|
250
|
260
|
200
|
|
CIMR-AU4A0362UAA
|
362
|
300
|
304
|
250
|
Flange
|
CIMR-AU4A0414UAA
|
414
|
350
|
370
|
300
|
|
CIMR-AU4A0515UAA
|
515
|
400
|
450
|
350
|
Flange
|
CIMR-AU4A0675UAA
|
675
|
500
|
605
|
400-500
|
|
CIMR-AU4A0930UAA4
|
930
|
700-800
|
810
|
600-700
|
Flange
|
CIMR-AU4A1200UAA4
|
1200
|
900-1000
|
1090
|
800-900
|
- Standard Enclosure can be conventionally mounted, or heatsink external (kit required for models CIMR-AU2A081FAA and smaller). Flange Enclosure includes special factory-installed gasketing and flange to provide NEMA 12 backside integrity when mounting heatsink external.
- Normal Duty overload current rating is 120% of rated output current for 60 seconds; Heavy Duty overload current rating is 150% of rated output current for 60 seconds
- Horsepower rating is based on standard NEMA B 4-pole motor design as represented in NEC table 430. 150 Full-Load Current, Three-Phase Alternating Current Motors
- Models CIMR-AU4A0930UAA and CIMR-AU4A1200UAA must be used with semiconductor input fuses and must be fed by a power source that has ground fault protection. A supplementary ground fault protection device can be added between the drive and the power source to address this requirement.
380-480V, 3-Phase,12-Pulse
Normal Duty (ND)2
|
Heavy Duty (HD)2
|
Enclosure1
|
|||
Rated Output Current (Amps)
|
Nominal HP3
|
Rated Output Current (Amps)
|
Nominal HP3
|
||
CIMR-AU4T0058UAA
|
58
|
40
|
45
|
30
|
Flange
|
CIMR-AU4T0072UAA
|
72
|
50
|
60
|
40
|
|
CIMR-AU4T0088UAA
|
88
|
60
|
75
|
50 & 60
|
Flange
|
CIMR-AU4T0103UAA
|
103
|
75
|
91
|
60
|
|
CIMR-AU4T0139UAA
|
139
|
100
|
112
|
75
|
Flange
|
CIMR-AU4T0165UAA
|
165
|
125
|
150
|
100
|
|
CIMR-AU4T0208UAA
|
208
|
150
|
180
|
125 & 150
|
Flange
|
CIMR-AU4T0250UAA
|
250
|
200
|
216
|
150
|
|
CIMR-AU4T0296UAA
|
296
|
250
|
260
|
200
|
|
CIMR-AU4T0362UAA
|
362
|
300
|
304
|
250
|
Flange
|
CIMR-AU4T0414UAA
|
414
|
350
|
370
|
300
|
|
CIMR-AU4T0515UAA
|
515
|
400
|
450
|
350
|
Flange
|
CIMR-AU4T0675UAA
|
675
|
500-600
|
605
|
400-500
|
|
See note 4
|
930
|
700-800
|
810
|
600-700
|
Fnlage
|
See note 4
|
1200
|
900-1000
|
1090
|
800-900
|
- Flange Enclosure includes special factory-installed gasketing and flange to provide NEMA 12 backside integrity when mounting heatsink external. Flange parts can be removed if conventional mounting is desired.
- Normal Duty overload current rating is 120% of rated output current for 60 seconds; Heavy Duty overload current rating is 150% of rated output current for 60 seconds.
- Horsepower rating is based on standard NEMA B 4-pole motor design as represented in NEC table 430.150 Full-Load Current, Three-Phase Alternating Current Motors.
- Models CIMR-AU4A0930xxx and CIMR-AU4A1200xxx are user configurable for either 6-Pulse (3-Phase) or 12-Pulse (6-Phase) input. See Standard 480V for model numbers.>
480V, Single-Phase Input, (460V Three-Phase Output)
Drive Model Number (NEMA 1 Compatible)
|
Single Phase Input – Sizing Method A (A)
(continuous full power) |
Single Phase Input – Sizing Method B (B)
(86% max power of connected motor size) |
|||||
Without Additional Reactor
|
With Additional Reactor
|
||||||
Motor Amps | Motor Size (HP) | Motor Amps | Motor Size (HP) |
Motor Amps
|
Motor Size (HP)
|
||
CIMR-AU4A0002FAA
|
0.8
|
1/3
|
1.1
|
1/2
|
0.8
|
1/3
|
|
CIMR-AU4A0004FAA
|
1.6
|
3/4
|
2.1
|
1
|
2.1
|
1
|
|
CIMR-AU4A0005FAA
|
2.1
|
1
|
3.0
|
1.5
|
3.0
|
1.5
|
|
CIMR-AU4A0007FAA
|
3.0
|
1.5
|
3.4
|
2
|
3.4
|
2
|
|
CIMR-AU4A0009FAA
|
3.4
|
2
|
4.8
|
3
|
4.8
|
3
|
|
CIMR-AU4A0011FAA
|
3.4
|
2
|
4.8
|
3
|
4.8
|
3
|
|
CIMR-AU4A0018FAA
|
4.8
|
3
|
4.8
|
3
|
7.6
|
5
|
|
CIMR-AU4A0023FAA
|
4.8
|
3
|
7.6
|
5
|
7.6
|
5
|
|
CIMR-AU4A0031FAA
|
11
|
7.5
|
11
|
7.5
|
14.0
|
10
|
|
CIMR-AU4A0038FAA
|
11
|
7.5
|
14
|
10
|
14.0
|
10
|
|
CIMR-AU4A0044FAA
|
14
|
10
|
14
|
10
|
21.0
|
15
|
|
CIMR-AU4A0058FAA
|
21
|
15
|
21
|
15
|
27.0
|
20
|
|
CIMR-AU4A0072FAA
|
27
|
20
|
27
|
20
|
34.0
|
25
|
|
CIMR-AU4A0088FAA
|
27
|
20
|
27
|
20
|
34.0
|
25
|
|
CIMR-AU4A0103FAA
|
27
|
20
|
27
|
20
|
34.0
|
25
|
|
CIMR-AU4A0139FAA
|
52
|
40
|
52
|
40
|
65.0
|
50
|
|
CIMR-AU4A0165FAA
|
52
|
40
|
52
|
40
|
65.0
|
50
|
|
CIMR-AU4A0208AAA
|
65
|
50
|
65
|
50
|
77.0
|
60
|
|
CIMR-AU4A0250AAA
|
77
|
60
|
77
|
60
|
96
|
75
|
|
CIMR-AU4A0296AAA
|
96
|
75
|
96
|
75
|
124
|
100
|
|
CIMR-AU4A0362AAA
|
124
|
100
|
124
|
100
|
156
|
125
|
|
CIMR-AU4A0414AAA
|
CIMR-UUX000679
|
156
|
125
|
156
|
125
|
180
|
150
|
CIMR-AU4A0515AAA
|
CIMR-UUX000680
|
156
|
125
|
156
|
125
|
180
|
150
|
CIMR-AU4A0675AAA
|
CIMR-UUX000681
|
180
|
150
|
180
|
150
|
240
|
200
|
- Standard Enclosure can be conventionally mounted, or heatsink external (kit required for models CIMR-AU2A0081FAA and smaller). Flange Enclosure includes special factory-installed gasketing and flange to provide NEMA 12 backside integrity when mounting heatsink external.
- Only models ending in FAA (CIMR-AU2A0211FAA and smaller) come standard with NEMA 1 End Cap Kits. Separately sold kits are available for larger models.
- For Flange Drives, use the sizing method above to determine proper drive size. Use selected model numbers with “UAA” suffix instead of “FAA” or “AAA” suffix.
- Use single phase input sizing method A for applications requiring more than 86% motor power. When sizing with additional reactor, refer to “Reactors for Single Phase Input” section of this price book. Caution: Adding more impedance than specified will degrade performance.
- Use single phase input sizing method B for applications requiring a maximum of 86% motor power.
500-600V, 3-Phase, Protected Chassis/NEMA 1
Normal Duty (ND)1
|
Heavy Duty (HD)1
|
Standard Enclosure
|
|||
Rated Output Current (Amps)
|
Nominal HP2
|
Rated Output Current (Amps)
|
Nominal HP2
|
||
CIMR-AU5A0003FAA
|
2.7
|
1 & 2
|
1.7
|
1
|
NEMA 1
|
CIMR-AU5A0004FAA
|
3.9
|
3
|
3.5
|
2
|
|
CIMR-AU5A0006FAA
|
6.1
|
5
|
4.1
|
3
|
|
CIMR-AU5A0009FAA
|
9
|
7.5
|
6.3
|
5
|
NEMA 1
|
CIMR-AU5A0011FAA
|
11
|
10
|
9.8
|
7.5
|
|
CIMR-AU5A0017FAA
|
17.5
|
15
|
12.5
|
10
|
|
CIMR-AU5A0022FAA
|
22
|
20
|
17
|
15
|
NEMA 1
|
CIMR-AU5A0027FAA
|
27
|
25
|
22
|
20
|
|
CIMR-AU5A0032FAA
|
32
|
30
|
27
|
25
|
|
CIMR-AU5A0041FAA
|
41
|
40
|
32
|
30
|
NEMA 1
|
CIMR-AU5A0052FAA
|
52
|
50
|
41
|
40
|
|
CIMR-AU5A0062FAA
|
62
|
60
|
52
|
50
|
|
CIMR-AU5A0077FAA
|
77
|
75
|
62
|
60
|
NEMA 1
|
CIMR-AU5A0099FAA
|
99
|
100
|
77
|
75
|
|
CIMR-AU5A0125AAA
|
125
|
125
|
99
|
100
|
Protected Chassis
|
CIMR-AU5A0145AAA
|
145
|
150
|
130
|
125
|
|
CIMR-AU5A0192AAA
|
192
|
200
|
172
|
150
|
Protected Chassis
|
CIMR-AU5A0242AAA
|
242
|
250
|
200
|
200
|
- Normal Duty overload current rating is 120% of rated output current for 60 seconds; Heavy Duty overload current rating is 150% of rated output current for 60 seconds
- Horsepower rating is based on standard NEMA B 4-pole motor design as represented in NEC table 430.150 Full-Load Current, Three-Phase Alternating Current Motors. Also, listed power ratings assumes three-phase input. For single-phase input applications, consult Manual Supplement TOEPYEASUP03 for proper sizing.
500-600V, 3-Phase, Flange
Normal Duty (ND)2
|
Heavy Duty (HD)2
|
Enclosure1
|
|||
Rated Output Current (Amps)
|
Nominal HP3
|
Rated Output Current (Amps)
|
Nominal HP3
|
||
CIMR-AU5A0003UAA
|
2.7
|
1 & 2
|
1.7
|
1
|
Flange
|
CIMR-AU5A0004UAA
|
3.9
|
3
|
3.5
|
2
|
|
CIMR-AU5A0006UAA
|
6.1
|
5
|
4.1
|
3
|
|
CIMR-AU5A0009UAA
|
9
|
7.5
|
6.3
|
5
|
Flange
|
CIMR-AU5A0011UAA
|
11
|
10
|
9.8
|
7.5
|
|
CIMR-AU5A0017UAA
|
17.5
|
15
|
12.5
|
10
|
|
CIMR-AU5A0022UAA
|
22
|
20
|
17
|
15
|
Flange
|
CIMR-AU5A0027UAA
|
27
|
25
|
22
|
20
|
|
CIMR-AU5A0032UAA
|
32
|
30
|
27
|
25
|
|
CIMR-AU5A0041UAA
|
41
|
40
|
32
|
30
|
Flange
|
CIMR-AU5A0052UAA
|
52
|
50
|
41
|
40
|
|
CIMR-AU5A0062UAA
|
62
|
60
|
52
|
50
|
|
CIMR-AU5A0077UAA
|
77
|
75
|
62
|
60
|
Flange
|
CIMR-AU5A0099UAA
|
99
|
100
|
77
|
75
|
|
CIMR-AU5A0125UAA
|
125
|
125
|
99
|
100
|
Flange
|
CIMR-AU5A0145UAA
|
145
|
150
|
130
|
125
|
|
CIMR-AU5A0192UAA
|
192
|
200
|
172
|
150
|
Flange
|
CIMR-AU5A0242UAA
|
242
|
250
|
200
|
200
|
- Standard Enclosure can be conventionally mounted, or heatsink external (kit required for models CIMR-AU2A081FAA and smaller). Flange Enclosure includes special factory-installed gasketing and flange to provide NEMA 12 backside integrity when mounting heatsink external.
- Normal Duty overload current rating is 120% of rated output current for 60 seconds; Heavy Duty overload current rating is 150% of rated output current for 60 seconds
- Horsepower rating is based on standard NEMA B 4-pole motor design as represented in NEC table 430. 150 Full-Load Current, Three-Phase Alternating Current Motors
600V, Single-Phase Input, (575V Three-Phase Output)
Single Phase Input – Sizing Method A (A)
(continuous full power) |
Single Phase Input – Sizing Method B (B)
(86% max power of connected motor size) |
|||||
Without Additional Reactor
|
With Additional Reactor
|
|||||
Motor Amps | Motor Size (HP) | Motor Amps | Motor Size (HP) |
Motor Amps
|
Motor Size (HP)
|
|
CIMR-AU5A0003FAA
|
1.7
|
1
|
2.4
|
1.5
|
1.7
|
1
|
CIMR-AU5A0004FAA
|
2.4
|
1.5
|
2.7
|
2
|
2.7
|
2
|
CIMR-AU5A0006FAA
|
2.7
|
2
|
3.9
|
3
|
3.9
|
3
|
CIMR-AU5A0009FAA
|
3.9
|
3
|
6.1
|
5
|
6.1
|
5
|
CIMR-AU5A0011FAA
|
2.7
|
2
|
3.9
|
3
|
3.9
|
3
|
CIMR-AU5A0017FAA
|
6.1
|
5
|
6.1
|
5
|
9.0
|
7.5
|
CIMR-AU5A0022FAA
|
6.1
|
5
|
7.5
|
9.0
|
9.0
|
7.5
|
CIMR-AU5A0027FAA
|
9.0
|
7.5
|
11
|
10
|
11.0
|
10
|
CIMR-AU5A0032FAA
|
9.0
|
7.5
|
11
|
10
|
11.0
|
10
|
CIMR-AU5A0041FAA
|
17
|
15
|
17
|
15
|
22.0
|
20
|
CIMR-AU5A0052FAA
|
17
|
15
|
17
|
15
|
22.0
|
20
|
CIMR-AU5A0062FAA
|
27
|
25
|
27
|
25
|
32.0
|
30
|
CIMR-AU5A0077FAA
|
32
|
30
|
32
|
30
|
41
|
40
|
CIMR-AU5A0099FAA
|
32
|
30
|
32
|
30
|
41
|
40
|
CIMR-AU5A0125AAA
|
52
|
50
|
52
|
50
|
62
|
60
|
CIMR-AU5A0145AAA
|
52
|
50
|
52
|
50
|
62
|
60
|
CIMR-AU5A0192AAA
|
77
|
75
|
77
|
75
|
99
|
100
|
CIMR-AU5A0242AAA
|
77
|
75
|
77
|
75
|
99
|
100
|
- Standard Enclosure can be conventionally mounted, or heatsink external (kit required for models CIMR-AU2A0081FAA and smaller). Flange Enclosure includes special factory-installed gasketing and flange to provide NEMA 12 backside integrity when mounting heatsink external.
- Only models ending in FAA (CIMR-AU2A0211FAA and smaller) come standard with NEMA 1 End Cap Kits. Separately sold kits are available for larger models.
- For Flange Drives, use the sizing method above to determine proper drive size. Use selected model numbers with “UAA” suffix instead of “FAA” or “AAA” suffix.
- Use single phase input sizing method A for applications requiring more than 86% motor power. When sizing with additional reactor, refer to “Reactors for Single Phase Input” section of this price book. Caution: Adding more impedance than specified will degrade performance.
- Use single phase input sizing method B for applications requiring a maximum of 86% motor power.
2. BIẾN TẦN G7 YASKAWA
208V
Catalog Model Number
|
Drive Model Number
|
Rated Output Current (Amps)
|
Nominal HP2
|
Standard Enclosure
|
CIMR-G7U20P41
|
CIMR-G7U20P41A
CIMR-G7U20P41B
|
3.2
|
1/2
|
NEMA 1
|
CIMR-G7U20P71
|
CIMR-G7U20P71A
CIMR-G7U20P71B
|
6
|
1
|
|
CIMR-G7U21P51
|
CIMR-G7U21P51A
CIMR-G7U21P51B
|
8
|
2
|
|
CIMR-G7U22P21
|
CIMR-G7U22P21A
CIMR-G7U22P21B
|
12
|
3
|
NEMA 1
|
CIMR-G7U23P71
|
CIMR-G7U23P71A
CIMR-G7U23P71B
|
18
|
5
|
|
CIMR-G7U25P51
|
CIMR-G7U25P51A
CIMR-G7U25P51B
|
27
|
7.5
|
NEMA 1
|
CIMR-G7U27P51
|
CIMR-G7U27P51A
CIMR-G7U27P51B
|
34
|
10
|
|
CIMR-G7U20111
|
CIMR-G7U20111A
CIMR-G7U20111B
|
49
|
15
|
NEMA 1
|
CIMR-G7U20151
|
CIMR-G7U20151A
CIMR-G7U20151B
|
66
|
20
|
|
CIMR-G7U20181
|
CIMR-G7U20181A
CIMR-G7U20181B
|
80
|
25
|
NEMA 1
|
CIMR-G7U20221
|
CIMR-G7U20221A
CIMR-G7U20221B
|
96
|
30
|
|
CIMR-G7U20300
|
CIMR-G7U20300A
CIMR-G7U20300B
|
130
|
40
|
Protected Chassis
|
CIMR-G7U20370
|
CIMR-G7U20370A
CIMR-G7U20370B
|
160
|
50
|
|
CIMR-G7U20450
|
CIMR-G7U20450A
CIMR-G7U20450B
|
183
|
60
|
Protected Chassis
|
CIMR-G7U20550
|
CIMR-G7U20550A
CIMR-G7U20550B
|
224
|
75
|
|
CIMR-G7U20750
|
CIMR-G7U20750A
CIMR-G7U20750B
|
300
|
100
|
Protected Chassis
|
CIMR-G7U20900
|
CIMR-G7U20900A
CIMR-G7U20900B
|
358
|
125
|
|
CIMR-G7U21100
|
CIMR-G7U21100A
CIMR-G7U21100B
|
415
|
150
|
- For single-phase input, contact Yaskawa
- Horsepower rating is based on standard NEMA B 4-pole motor design as represented in NEC table 430.150 Full-Load Current, Three-Phase Alternating Current Motors
- Check motor FLA for proper drive sizing
240V
Catalog Model Number
|
Drive Model Number
|
Rated Output Current (Amps)
|
Nominal HP2
|
Standard Enclosure
|
CIMR-G7U20P41
|
CIMR-G7U20P41A
CIMR-G7U20P41B
|
3.2
|
3/4
|
NEMA 1
|
CIMR-G7U20P71
|
CIMR-G7U30P71A
CIMR-G7U30P71B
|
6
|
1
|
|
CIMR-G7U21P51
|
CIMR-G7U21P51A
CIMR-G7U21P51B
|
8
|
2
|
NEMA 1
|
CIMR-G7U22P21
|
CIMR-G7U22P21A
CIMR-G7U22P21B
|
12
|
3
|
|
CIMR-G7U23P71
|
CIMR-G7U23P71A
CIMR-G7U23P71B
|
18
|
5
|
NEMA 1
|
CIMR-G7U25P51
|
CIMR-G7U25P51A
CIMR-G7U25P51B
|
27
|
7.5
|
|
CIMR-G7U27P51
|
CIMR-G7U27P51A
CIMR-G7U27P51B
|
34
|
10
|
NEMA 1
|
CIMR-G7U20111
|
CIMR-G7U20111A
CIMR-G7U20111B
|
49
|
15
|
|
CIMR-G7U20151
|
CIMR-G7U20151A
CIMR-G7U20151B
|
66
|
20
|
NEMA 1
|
CIMR-G7U20181
|
CIMR-G7U20181A
CIMR-G7U20181C
|
80
|
25
|
NEMA 1
|
30
|
||||
CIMR-G7U20221
|
CIMR-G7U20221A
CIMR-G7U20221B
|
96
|
303
|
NEMA 1
|
CIMR-G7U20300
|
CIMR-G7U20300A
CIMR-G7U20300B
|
130
|
40
|
Protected Chassis
|
50
|
- For single-phase input, contact Yaskawa
- Horsepower rating is based on standard NEMA B 4-pole motor design as represented in NEC table 430.150 Full-Load Current, Three-Phase Alternating Current Motors
- Check motor FLA for proper drive sizing
230V
Catalog Model Number
|
Drive Model Number
|
Rated Output Current (Amps)
|
Nominal HP2
|
Standard Enclosure
|
CIMR-G7U20370
|
CIMR-G7U20370A
CIMR-G7U20370B
|
160
|
60
|
Protected Chassis
|
CIMR-G7U20450
|
CIMR-G7U20450A
CIMR-G7U20450B
|
183
|
603
|
|
CIMR-G7U20550
|
CIMR-G7U20550A
CIMR-G7U20550B
|
224
|
75
|
Protected Chassis
|
CIMR-G7U20750
|
CIMR-G7U20750A
CIMR-G7U20750B
|
300
|
100
|
|
CIMR-G7U20900
|
CIMR-G7U20900A
CIMR-G7U20900B
|
358
|
125
|
Protected Chassis
|
CIMR-G7U21100
|
CIMR-G7U21100A
CIMR-G7U21100B
|
415
|
150
|
- For single-phase input, contact Yaskawa
- Horsepower rating is based on standard NEMA B 4-pole motor design as represented in NEC table 430.150 Full-Load Current, Three-Phase Alternating Current Motors
- Check motor FLA for proper drive sizing
480V
Catalog Model Number
|
Drive Model Number
|
Rated Output Current (Amps)
|
Nominal HP2
|
Standard Enclosure
|
CIMR-G7U40P41
|
CIMR-G7U40P41A
CIMR-G7U40P41B
|
1.8
|
3/4
|
NEMA 1
|
CIMR-G7U40P71
|
CIMR-G7U40P71A
CIMR-G7U40P71B
|
3.4
|
1
|
NEMA 1
|
2
|
||||
CIMR-G7U41P51
|
CIMR-G7U41P51A
CIMR-G7U41P51B
|
4.8
|
3
|
NEMA 1
|
CIMR-G7U42P21
|
CIMR-G7U42P21A
CIMR-G7U42P21B
|
6.2
|
33
|
|
CIMR-G7U43P71
|
CIMR-G7U43P71A
CIMR-G7U43P71B
|
9
|
5
|
NEMA 1
|
CIMR-G7U44P01
|
CIMR-G7U44P01A
CIMR-G7U44P01B
|
11
|
7.5
|
|
CIMR-G7U45P51
|
CIMR-G7U45P51A
CIMR-G7U45P51B
|
15
|
10
|
NEMA 1
|
CIMR-G7U47P51
|
CIMR-G7U47P51A
CIMR-G7U47P51B
|
21
|
15
|
|
CIMR-G7U40111
|
CIMR-G7U40111A
CIMR-G7U40111B
|
27
|
20
|
NEMA 1
|
CIMR-G7U40151
|
CIMR-G7U40151A
CIMR-G7U40151B
|
34
|
25
|
|
CIMR-G7U40181
|
CIMR-G7U40181A
CIMR-G7U40181B
|
42
|
30
|
NEMA 1
|
CIMR-G7U40221
|
CIMR-G7U40221A
CIMR-G7U40221B
|
52
|
40
|
|
CIMR-G7U40301
|
CIMR-G7U40301A
CIMR-G7U40301B
|
65
|
50
|
NEMA 1
|
CIMR-G7U40371
|
CIMR-G7U40371A
CIMR-G7U40371B
|
80
|
60
|
|
CIMR-G7U40451
|
CIMR-G7U40451A
CIMR-G7U40451B
|
97
|
75
|
|
CIMR-G7U40550
|
CIMR-G7U40550A
CIMR-G7U40550B
|
128
|
100
|
Protected Chassis
|
CIMR-G7U40750
|
CIMR-G7U40750A
CIMR-G7U40750B
|
165
|
125
|
|
CIMR-G7U40900
|
CIMR-G7U40900A
CIMR-G7U40900B
|
195
|
150
|
Protected Chassis
|
CIMR-G7U41100
|
CIMR-G7U41100A
CIMR-G7U41100B
|
240
|
200
|
|
CIMR-G7U41320
|
CIMR-G7U41320A
CIMR-G7U41320B
|
270
|
2003
|
Protected Chassis
|
CIMR-G7U41600
|
CIMR-G7U41600A
CIMR-G7U41600B
|
302
|
250
|
|
CIMR-G7U41850
|
CIMR-G7U41850A
CIMR-G7U41850B
|
370
|
300
|
Protected Chassis
|
CIMR-G7U42200
|
CIMR-G7U42200A
CIMR-G7U42200B
|
450
|
350
|
|
CIMR-G7U43000
|
CIMR-G7U43000A
|
605
|
400
|
Protected Chassis
|
500
|
- For single-phase input, contact Yaskawa
- Horsepower rating is based on standard NEMA B 4-pole motor design as represented in NEC table 430.150 Full-Load Current, Three-Phase Alternating Current Motors
- Check motor FLA for proper drive sizing
3. BIẾN TẦN V1000 YASKAWA
200-240V, 1-Phase
- Normal Duty overload current rating is 120% of rated output current for 60 seconds; Heavy Duty overload current rating is 150% of rated output current for 60 seconds
- Horsepower rating is based on 230 Volt and 460 Volt Induction-Type Squirrel Cage NEMA B 4-Pole Motors as represented in NEC Table 430.250 Full-Load Current, Three-Phase Alternating-Current Motors.
200-240V, 3-Phase
- Normal Duty overload current rating is 120% of rated output current for 60 seconds; Heavy Duty overload current rating is 150% of rated output current for 60 seconds
- Horsepower rating is based on 230 Volt and 460 Volt Induction-Type Squirrel Cage NEMA B 4-Pole Motors as represented in NEC Table 430.250 Full-Load Current, Three-Phase Alternating-Current Motors.
380-480V 3-Phase
- Normal Duty overload current rating is 120% of rated output current for 60 seconds; Heavy Duty overload current rating is 150% of rated output current for 60 seconds
- Horsepower rating is based on 230 Volt and 460 Volt Induction-Type Squirrel Cage NEMA B 4-Pole Motors as represented in NEC Table 430.250 Full-Load Current, Three-Phase Alternating-Current Motors.
4. BIẾN TẤN P1000 YASKAWA
200-240V, 3-Phase
Rated Output Current (Amps)
|
Nominal HP 3
|
Standard Enclosure 1, 2
|
|
CIMR-PU2A0004FAA
|
3.5
|
3/4
|
NEMA 1
|
CIMR-PU2A0006FAA
|
6
|
1
|
|
CIMR-PU2A0008FAA
|
8
|
2
|
|
CIMR-PU2A0010FAA
|
9.6
|
2
|
NEMA 1
|
CIMR-PU2A0012FAA
|
12
|
3
|
|
CIMR-PU2A0018FAA
|
17.5
|
5
|
|
CIMR-PU2A0021FAA
|
21
|
7.5
|
NEMA 1
|
CIMR-PU2A0030FAA
|
30
|
10
|
|
CIMR-PU2A0040FAA
|
40
|
15
|
|
CIMR-PU2A0056FAA
|
56
|
20
|
NEMA 1
|
CIMR-PU2A0069FAA
|
69
|
25
|
|
CIMR-PU2A0081FAA
|
81
|
30
|
|
CIMR-PU2A0110FAA
|
110
|
40
|
NEMA 1
|
CIMR-PU2A0138FAA
|
138
|
50
|
|
CIMR-PU2A0169FAA
|
169
|
60
|
NEMA 1
|
CIMR-PU2A0211FAA
|
211
|
75
|
|
CIMR-PU2A0250AAA
|
250
|
100
|
Protected Chassis
|
CIMR-PU2A0312AAA
|
312
|
125
|
|
CIMR-PU2A0360AAA
|
360
|
150
|
Protected Chassis
|
CIMR-PU2A0415AAA
|
415
|
175
|
- Standard Enclosure can be conventionally mounted, or heatsink external (kit required for models CIMR-PU2A081FAA and smaller).
- Only models ending in FAA (CIMR-PU2A0211FAA and smaller) come standard with NEMA 1 End Cap Kits. Separately sold kits are available for larger models.
- Horsepower rating is based on standard NEMA B 4-pole motor design as represented in NEC table 430.150 Full-Load Current, Three-Phase Alternating Current Motors. Also, listed power ratings assumes three-phase input. For single-phase input applications, consult Manual Supplement TOEPYEASUP03 for proper sizing.
200-240V, 1-Phase
Single Phase Input – Sizing Method AA
(Continuous Full Power) |
Single Phase Input – Sizing Method BB
(86% max power of connected motor size) |
|||||
Without Additional Reactor
|
With Additional Reactor
|
Motor Amps | Motor Size (HP) | |||
Motor Amps | Motor Size (HP) | Motor Amps | Motor Size (HP) | |||
CIMR-PU2A0004FAA
|
1.7
|
1/3
|
2.4
|
1/2
|
3.5
|
3/4
|
CIMR-PU2A0006FAA
|
3.5
|
3/4
|
3.5 |
3/4
|
4.6
|
1
|
CIMR-PU2A0008FAA
|
4.6
|
1
|
4.6
|
1
|
6.6
|
1.5
|
CIMR-PU2A0010FAA
|
4.6 |
1
|
4.6
|
1
|
6.6
|
1.5
|
CIMR-PU2A0012FAA
|
6.6
|
1.5
|
7.5
|
2
|
7.5
|
2
|
CIMR-PU2A0018FAA
|
7.5 |
2
|
10.6
|
3
|
10.6
|
3
|
CIMR-PU2A0021FAA
|
7.5
|
2
|
10.6
|
3
|
10.6
|
3
|
CIMR-PU2A0030FAA
|
10.6
|
2
|
10.6
|
3
|
17
|
5
|
CIMR-PU2A0040FAA
|
10.6
|
3
|
17
|
5
|
17
|
5
|
CIMR-PU2A0056FAA
|
17
|
5
|
24
|
7.5
|
24
|
7.5
|
CIMR-PU2A0069FAA
|
24
|
7.5
|
31
|
10
|
31
|
10
|
CIMR-PU2A0081FAA
|
31
|
10
|
31
|
10
|
46
|
15
|
CIMR-PU2A0110FAA
|
31
|
10
|
46
|
15
|
46
|
15
|
CIMR-PU2A0138FAA
|
46
|
15
|
46
|
15
|
59
|
20
|
CIMR-PU2A0169FAA
|
59
|
20
|
59
|
20
|
75
|
25
|
CIMR-PU2A0211FAA
|
75
|
25
|
75
|
25
|
88
|
30
|
CIMR-PU2A0250FAA
|
88
|
30
|
88
|
30
|
114
|
40
|
CIMR-PU2A0312FAA
|
114
|
40
|
114
|
40
|
143
|
50
|
CIMR-PU2A0360FAA
|
143
|
50
|
143
|
50
|
169
|
60
|
CIMR-PU2A0415FAA
|
169
|
60
|
169
|
60
|
211
|
75
|
- Standard Enclosure can be conventionally mounted, or heatsink external (kit required for models CIMR-PU2A0081FAA and smaller). Flange Enclosure includes special factory-installed gasketing and flange to provide NEMA 12 backside integrity when mounting heatsink external.
- Only models ending in FAA (CIMR-PU2A0211FAA and smaller) come standard with NEMA 1 End Cap Kits. Separately sold kits are available for larger models.
- For Flange Drives, use the Sizing Method above to determine proper drive size. Use selected model number with “UAA” suffix instead of “FAA” or “AAA” suffix.(A) Use single-phase input sizing method A for applications requiring more than 86% motor power. When sizing with additional reactor, refer to “Reactors for Single Phase Input” under P1000 Power Options on this site. Caution: Adding more impedance than specified will degrade performance.
(B) Use single-phase input sizing method B for applications requiring a maximum of 86% motor power.
200-240V, 3-Phase, Flange
Rated Output Current (Amps)
|
Nominal HP 2
|
Enclosure 1
|
|
CIMR-PU2A0004UAA
|
3.5
|
3/4
|
Flange
|
CIMR-PU2A0006UAA
|
6
|
1
|
|
CIMR-PU2A0008UAA
|
8
|
2
|
|
CIMR-PU2A0010UAA
|
9.6
|
3
|
Flange
|
CIMR-PU2A0012UAA
|
12
|
3
|
|
CIMR-PU2A0018UAA
|
17.5
|
5
|
|
CIMR-PU2A0021UAA
|
21
|
7.5
|
Flange
|
CIMR-PU2A0030UAA
|
30
|
10
|
|
CIMR-PU2A0040UAA
|
40
|
15
|
|
CIMR-PU2A0056UAA
|
56
|
20
|
Flange
|
CIMR-PU2A0069UAA
|
69
|
25
|
|
CIMR-PU2A0081UAA
|
81
|
30
|
|
CIMR-PU2A0110UAA
|
110
|
40
|
Flange
|
CIMR-PU2A0138UAA
|
138
|
50
|
|
CIMR-PU2A0169UAA
|
169
|
60
|
|
CIMR-PU2A0211UAA
|
211
|
75
|
Flange
|
CIMR-PU2A0250UAA
|
250
|
100
|
|
CIMR-PU2A0312UAA
|
312
|
125
|
|
CIMR-PU2A0360UAA
|
360
|
150
|
Flange
|
CIMR-PU2A0415UAA
|
415
|
175
|
- Flange Enclosure includes special factory-installed gasketing and flange to provide NEMA 12 backside integrity when mounting heatsink external.
- Horsepower rating is based on standard NEMA B 4-pole motor design as represented in NEC table 430.150 Full-Load Current, Three-Phase Alternating Current Motors. Also, listed power ratings assumes three-phase input. For single-phase input applications, consult Manual Supplement TOEPYEASUP03 for proper sizing.
380-480V, 3-Phase, Standard
Rated Output Current (Amps)
|
Nominal HP 3
|
Standard Enclosure 1, 2
|
|
CIMR-PU4A0002FAA
|
2.1
|
1
|
NEMA 1
|
CIMR-PU4A0004FAA
|
4.1
|
2
|
|
CIMR-PU4A0005FAA
|
5.4
|
3
|
|
CIMR-PU4A0007FAA
|
6.9
|
4
|
NEMA 1
|
CIMR-PU4A0009FAA
|
8.8
|
5
|
|
CIMR-PU4A0011FAA
|
11.1
|
7.5
|
|
CIMR-PU4A0018FAA
|
17.5
|
10
|
NEMA 1
|
CIMR-PU4A0023FAA
|
23
|
15
|
|
CIMR-PU4A0031FAA
|
31
|
20
|
|
CIMR-PU4A0038FAA
|
38
|
25
|
NEMA 1
|
CIMR-PU4A0044FAA
|
44
|
30
|
|
CIMR-PU4A0058FAA
|
58
|
40
|
|
CIMR-PU4A0072FAA
|
72
|
50
|
NEMA 1
|
CIMR-PU4A0088FAA
|
88
|
60
|
|
CIMR-PU4A0103FAA
|
103
|
75
|
|
CIMR-PU4A0139FAA
|
139
|
100
|
NEMA 1
|
CIMR-PU4A0165FAA
|
165
|
125
|
|
CIMR-PU4A0208AAA
|
208
|
150
|
Protected Chassis
|
CIMR-PU4A0250AAA
|
250
|
200
|
|
CIMR-PU4A0296AAA
|
296
|
250
|
|
CIMR-PU4A0362AAA
|
362
|
300
|
Protected Chassis
|
CIMR-PU4A0414AAA
|
414
|
350
|
|
CIMR-PU4A0515AAA
|
515
|
400
|
Protected Chassis
|
CIMR-PU4A0675AAA
|
675
|
500
|
|
CIMR-PU4A0930AAA
|
930
|
700-800
|
Protected Chassis
|
CIMR-PU4A1200AAA
|
1200
|
900-1000
|
- Standard Enclosure can be conventionally mounted, or heatsink external (kit required for models CIMR-PU4A044FAA and smaller).
- Only models ending in FAA (CIMR-PU4A0165FAA and smaller) come standard with NEMA 1 End Cap Kits. Separately sold kits are available for larger models.
- Horsepower rating is based on standard NEMA B 4-pole motor design as represented in NEC table 430.150 Full-Load Current, Three-Phase Alternating Current Motors. Also, listed power ratings assumes three-phase input. For single-phase input applications, consult Manual Supplement TOEPYEASUP03 for proper sizing.
- Models CIMR-PU4A0930AAA and CIMR-PU4A1200AAA must be used with semiconductor input fuses and must be fed by a power source that has ground fault protection. A supplementary ground fault protection device can be added between the drive and the power source to address this requirement.
380-480V, 1-Phase, Standard
Single Phase Input – Sizing Method AA
(Continuous Full Power) |
Single Phase Input – Sizing Method BB
(86% max power of connected motor size) |
|||||
Without Additional Reactor
|
With Additional Reactor
|
Motor Amps | Motor Size (HP) | |||
Motor Amps | Motor Size (HP) | Motor Amps | Motor Size (HP) | |||
CIMR-PU4A0002FAA
|
0.8
|
1/3
|
1.1
|
1/2
|
1.6
|
3/4
|
CIMR-PU4A0004FAA
|
1.6
|
3/4
|
2.1 |
1
|
2.1
|
1
|
CIMR-PU4A0005FAA
|
2.1
|
1
|
3
|
1.5
|
3.4
|
2
|
CIMR-PU4A0007FAA
|
3.0
|
1.5
|
3.4
|
2
|
3.4
|
2
|
CIMR-PU4A0009FAA
|
3.4
|
2
|
4.8
|
3
|
4.8
|
3
|
CIMR-PU4A0011FAA
|
3.4
|
2
|
4.8
|
3
|
4.8
|
3
|
CIMR-PU4A0018FAA
|
4.8
|
3
|
4.8
|
3
|
7.6
|
5
|
CIMR-PU4A0023FAA
|
4.8
|
3
|
7.6
|
5
|
7.6
|
5
|
CIMR-PU4A0031FAA
|
11
|
7.5
|
11
|
7.5
|
14
|
10
|
CIMR-PU4A0038FAA
|
11
|
7.5
|
14
|
10
|
14
|
10
|
CIMR-PU4A0044FAA
|
14
|
10
|
14
|
10
|
21
|
15
|
CIMR-PU4A0058FAA
|
21
|
15
|
21
|
15
|
27
|
20
|
CIMR-PU4A0072FAA
|
27
|
20
|
27
|
20
|
34
|
25
|
CIMR-PU4A0088FAA
|
27
|
20
|
27
|
20
|
34
|
25
|
CIMR-PU4A0103FAA
|
27
|
20
|
27
|
20
|
34
|
25
|
CIMR-PU4A0139FAA
|
52
|
40
|
52
|
40
|
65
|
50
|
CIMR-PU4A0165FAA
|
52
|
40
|
52
|
40
|
65
|
50
|
CIMR-PU4A0208FAA
|
65
|
50
|
65
|
50
|
77
|
60
|
CIMR-PU4A0250FAA
|
77
|
60
|
77
|
60
|
96
|
75
|
CIMR-PU4A0296FAA
|
96
|
75
|
96
|
75
|
124
|
100
|
CIMR-PU4A0362FAA
|
124
|
100
|
124
|
100
|
156
|
125
|
CIMR-PU4A0414FAA
|
156
|
125
|
156
|
125
|
180
|
150
|
CIMR-PU4A0515FAA
|
156
|
125
|
156
|
125
|
180
|
150
|
CIMR-PU4A0675FAA
|
180
|
150
|
180
|
150
|
240
|
200
|
- Standard Enclosure can be conventionally mounted, or heatsink external (kit required for models CIMR-PU4A0044FAA and smaller). Flange Enclosure includes special factory-installed gasketing and flange to provide NEMA 12 backside integrity when mounting heatsink external.
- Only models ending in FAA (CIMR-PU4A0165FAA and smaller) come standard with NEMA 1 End Cap Kits. Separately sold kits are available for larger models.
- For Flange Drives, use the Sizing Method above to determine proper drive size. Use selected model number with “UAA” suffix instead of “FAA” or “AAA” suffix.(A) Use single-phase input sizing method A for applications requiring more than 86% motor power. When sizing with additional reactor, refer to “Reactors for Single Phase Input” under P1000 Power Options on this site. Caution: Adding more impedance than specified will degrade performance.
(B) Use single-phase input sizing method B for applications requiring a maximum of 86% motor power.
380-480V, 3-Phase, Flange
|
Nominal HP2
|
Enclosure1
|
|
CIMR-PU4A0002UAA
|
2.1
|
1
|
Flange
|
CIMR-PU4A0004UAA
|
4.1
|
2
|
|
CIMR-PU4A0005UAA
|
5.4
|
3
|
|
CIMR-PU4A0007UAA
|
6.9
|
4
|
Flange
|
CIMR-PU4A0009UAA
|
8.8
|
5
|
|
CIMR-PU4A0011UAA
|
11.1
|
7.5
|
|
CIMR-PU4A0018UAA
|
17.5
|
10
|
Flange
|
CIMR-PU4A0023UAA
|
23
|
15
|
|
CIMR-PU4A0031UAA
|
31
|
20
|
|
CIMR-PU4A0038UAA
|
38
|
25
|
Flange
|
CIMR-PU4A0044UAA
|
44
|
30
|
|
CIMR-PU4A0058UAA
|
58
|
40
|
|
CIMR-PU4A0072UAA
|
72
|
50
|
Flange
|
CIMR-PU4A0088UAA
|
88
|
60
|
|
CIMR-PU4A0103UAA
|
103
|
75
|
|
CIMR-PU4A0139UAA
|
139
|
100
|
Flange
|
CIMR-PU4A0165UAA
|
165
|
125
|
|
CIMR-PU4A0208UAA
|
208
|
150
|
Flange
|
CIMR-PU4A0250UAA
|
250
|
200
|
|
CIMR-PU4A0296UAA
|
296
|
250
|
|
CIMR-PU4A0362UAA
|
362
|
300
|
Flange
|
CIMR-PU4A0414UAA
|
414
|
350
|
|
CIMR-PU4A0515UAA
|
515
|
400
|
Flange
|
CIMR-PU4A0675UAA
|
675
|
500
|
|
CIMR-PU4A0930UAA3
|
930
|
700-800
|
Flange
|
CIMR-PU4A1200UAA3
|
1200
|
900-1000
|
- Flange Enclosure includes special factory-installed gasketing and flange to provide NEMA 12 backside integrity when mounting heatsink external.
- Horsepower rating is based on standard NEMA B 4-pole motor design as represented in NEC table 430.150 Full-Load Current, Three-Phase Alternating Current Motors. Also, listed power ratings assumes three-phase input. For single-phase input applications, consult Manual Supplement TOEPYEASUP03 for proper sizing.
- Models CIMR-PU4A0930UAA and CIMR-PU4A1200UAA must be used with semiconductor input fuses and must be fed by a power source that has ground fault protection. A supplementary ground fault protection device can be added between the drive and the power source to address this requirement.
380-480V, 3-Phase, 12-Pulse Flange
Rated Output Current (Amps)
|
Nominal HP2
|
Enclosure1
|
|
CIMR-PU4T0058UAA
|
58
|
40
|
Flange
|
CIMR-PU4T0072UAA
|
72
|
50
|
|
CIMR-PU4T0088UAA
|
88
|
60
|
Flange
|
CIMR-PU4T0103UAA
|
103
|
75
|
|
CIMR-PU4T0139UAA
|
139
|
100
|
Flange
|
CIMR-PU4T0165UAA
|
165
|
125
|
|
CIMR-PU4T0208UAA
|
208
|
150
|
Flange
|
CIMR-PU4T0250UAA
|
250
|
200
|
|
CIMR-PU4T0296UAA
|
296
|
250
|
|
CIMR-PU4T0362UAA
|
362
|
300
|
Flange
|
CIMR-PU4T0414UAA
|
414
|
350
|
|
CIMR-PU4T0515UAA
|
515
|
400
|
Flange
|
CIMR-PU4T0675UAA
|
675
|
500
|
|
See note 3
|
930
|
700-800
|
Flange
|
See note 3
|
1200
|
900-1000
|
- Flange Enclosure includes special factory-installed gasketing and flange to provide NEMA 12 backside integrity when mounting heatsink external. Flange parts can be removed if convential mounting is desired.
- Horsepower rating is based on standard NEMA B 4-pole motor design as represented in NEC table 430.150 Full-Load Current, Three-Phase Alternating Current Motors.
- Models CIMR-PU4A0930xxx and CIMR-PU4A1200xxx are user configurable for either 6-Pulse (3-Phase) or 12-Pulse (6-Phase) input. See Standard 480V for model numbers.
500-600V, 3-Phase, Standard
Rated Output Current (Amps)
|
Nominal HP 3
|
Standard Enclosure 1, 2
|
|
CIMR-PU5A0003FAA
|
2.7
|
1 & 2
|
NEMA 1
|
CIMR-PU5A0004FAA
|
3.9
|
3
|
|
CIMR-PU5A0006FAA
|
6.1
|
5
|
|
CIMR-PU5A0009FAA
|
9
|
7.5
|
NEMA 1
|
CIMR-PU5A0011FAA
|
11
|
10
|
|
CIMR-PU5A0017FAA
|
17.5
|
15
|
|
CIMR-PU5A0022FAA
|
22
|
20
|
NEMA 1
|
CIMR-PU5A0027FAA
|
27
|
25
|
|
CIMR-PU5A0032FAA
|
32
|
30
|
|
CIMR-PU5A0041FAA
|
41
|
40
|
NEMA 1
|
CIMR-PU5A0052FAA
|
52
|
50
|
|
CIMR-PU5A0062FAA
|
62
|
60
|
|
CIMR-PU5A0077FAA
|
77
|
75
|
NEMA 1
|
CIMR-PU5A0099FAA
|
99
|
100
|
|
CIMR-PU5A0125AAA
|
125
|
125
|
Protected Chassis
|
CIMR-PU5A0145AAA
|
145
|
150
|
|
CIMR-PU5A0192AAA
|
192
|
200
|
Protected Chassis
|
CIMR-PU5A0242AAA
|
242
|
250
|
- Standard Enclosure can be conventionally mounted, or heatsink external (kit required for models CIMR-PU5A032FAA and smaller).
- Only models ending in FAA (CIMR-PU5A0099FAA and smaller) come standard with NEMA 1 End Cap Kits. Separately sold kits are available for larger models.
- Horsepower rating is based on standard NEMA B 4-pole motor design as represented in NEC table 430.150 Full-Load Current, Three-Phase Alternating Current Motors. Also, listed power ratings assumes three-phase input. For single-phase input applications, consult Manual Supplement TOEPYEASUP03 for proper sizing.
500-600V, 1-Phase, Standard
Single Phase Input – Sizing Method AA
(Continuous Full Power) |
Single Phase Input – Sizing Method BB
(86% max power of connected motor size) |
|||||
Without Additional Reactor
|
With Additional Reactor
|
Motor Amps | Motor Size (HP) | |||
Motor Amps | Motor Size (HP) | Motor Amps | Motor Size (HP) | |||
CIMR-PU5A0003FAA
|
1.7
|
1
|
2.4
|
1.5
|
1.7
|
1
|
CIMR-PU5A0004FAA
|
2.4
|
1.5
|
2.7 |
2
|
2.7
|
2
|
CIMR-PU5A0006FAA
|
2.7
|
2
|
3.9
|
3
|
3.9
|
3
|
CIMR-PU5A0009FAA
|
3.9
|
3
|
6.1
|
5
|
6.1
|
5
|
CIMR-PU5A0011FAA
|
2.7
|
2
|
3.9
|
3
|
3.9
|
3
|
CIMR-PU5A0017FAA
|
6.1
|
5
|
6.1
|
5
|
9
|
7.5
|
CIMR-PU5A0022FAA
|
6.1
|
5
|
9
|
7.5
|
9
|
7.5
|
CIMR-PU5A0027FAA
|
9
|
7.5
|
11
|
10
|
11
|
10
|
CIMR-PU5A0032FAA
|
9
|
7.5
|
11
|
10
|
11
|
10
|
CIMR-PU5A0041FAA
|
17
|
15
|
17
|
15
|
22
|
20
|
CIMR-PU5A0052FAA
|
17
|
15
|
17
|
15
|
22
|
20
|
CIMR-PU5A0062FAA
|
27
|
25
|
27
|
25
|
32
|
30
|
CIMR-PU5A0077FAA
|
32
|
30
|
32
|
30
|
41
|
40
|
CIMR-PU5A0099FAA
|
32
|
30
|
32
|
30
|
41
|
40
|
CIMR-PU5A0125FAA
|
52
|
50
|
52
|
50
|
62
|
60
|
CIMR-PU5A0145FAA
|
52
|
50
|
52
|
50
|
62
|
60
|
CIMR-PU5A0192FAA
|
77
|
75
|
77
|
75
|
99
|
100
|
CIMR-PU5A0242FAA
|
77
|
75
|
77
|
75
|
99
|
100
|
- Standard Enclosure can be conventionally mounted, or heatsink external (kit required for models CIMR-PU5A0032FAA and smaller). Flange Enclosure includes special factory-installed gasketing and flange to provide NEMA 12 backside integrity when mounting heatsink external.
- Only models ending in FAA (CIMR-PU5A0099FAA and smaller) come standard with NEMA 1 End Cap Kits. Separately sold kits are available for larger models.
- For Flange Drives, use the Sizing Method above to determine proper drive size. Use selected model number with “UAA” suffix instead of “FAA” or “AAA” suffix.(A) Use single-phase input sizing method A for applications requiring more than 86% motor power. When sizing with additional reactor, refer to “Reactors for Single Phase Input” under P1000 Power Options on this site. Caution: Adding more impedance than specified will degrade performance.
(B) Use single-phase input sizing method B for applications requiring a maximum of 86% motor power.
500-600V, 3-Phase, Flange
Rated Output Current (Amps)
|
Nominal HP2
|
Enclosure1
|
|
CIMR-PU5A0003UAA
|
2.7
|
1 & 2
|
Flange
|
CIMR-PU5A0004UAA
|
3.9
|
3
|
|
CIMR-PU5A0006UAA
|
6.1
|
5
|
|
CIMR-PU5A0009UAA
|
9
|
7.5
|
Flange
|
CIMR-PU5A0011UAA
|
11
|
10
|
|
CIMR-PU5A0017UAA
|
17.5
|
15
|
|
CIMR-PU5A0022UAA
|
22
|
20
|
Flange
|
CIMR-PU5A0027UAA
|
27
|
25
|
|
CIMR-PU5A0032UAA
|
32
|
30
|
|
CIMR-PU5A0041UAA
|
41
|
40
|
Flange
|
CIMR-PU5A0052UAA
|
52
|
50
|
|
CIMR-PU5A0062UAA
|
62
|
60
|
|
CIMR-PU5A0077UAA
|
77
|
75
|
Flange
|
CIMR-PU5A0099UAA
|
99
|
100
|
|
CIMR-PU5A0125UAA
|
125
|
125
|
Flange
|
CIMR-PU5A0145UAA
|
145
|
150
|
|
CIMR-PU5A0192UAA
|
192
|
200
|
Flange
|
CIMR-PU5A0242UAA
|
242
|
250
|
- Flange Enclosure includes special factory-installed gasketing and flange to provide NEMA 12 backside integrity when mounting heatsink external. Flange parts can be removed if conventional mounting is desired.
- Horsepower rating is based on standard NEMA B 4-pole motor design as represented in NEC table 430.150 Full-Load Current, Three-Phase Alternating Current Motors.
- Models CIMR-PU4A0930xxx and CIMR-PU4A1200xxx are user configurable for either 6-Pulse (3-Phase) or 12-Pulse (6-Phase) input. See Standard 480V price page on page 4 for model numbers and prices.